Switching Power Supply UL Series LED Driver 12V 36W
Certificate No. UL-CA-2217599-0
Features
▲Universal AC input 100–240V, up to 87.4%
▲efficiency
▲Protection: short circuit / overload /
▲overvoltage; 36W; natural air cooling
▲PWM control circuit
▲100% full-load burn-in test
▲1-year warranty
Product Details
| Electrical Specs | |||
|---|---|---|---|
| Model | ZRY-603P36-V1 | ||
| Output | DC voltage | 12V | |
| Rated current | 3A | ||
| Current Range (Natural Cooling) | 0-3A | ||
| Rated power (natural cooling) | 36W | ||
| Ripple and noise | 120mVp-p | ||
| Voltage adjustment range | 11.40V-12.60V | ||
| Voltage accuracy | ±5.0% | ||
| Linear adjustment rate | ±0.3% | ||
| Load regulation rate | ±1.0% | ||
| Launch, rise time | 800mS,50mS/230VAC 1600mS,60mS/115VAC (When fully loaded) | ||
| Keep the time | 15mS/230VAC 15mS/115VAC (When fully loaded) | ||
| Input | Operating voltage and frequency | 90~264VAC或127~370VDC 47-63Hz | |
| Efficiency | 0.87 | ||
| AC current | 1.0A/115VAC 0.5A/230VAC | ||
| Surging currents | Cold start:30A | ||
| Leakage current | <3mA/240VAC | ||
| Protection | Overload | Rated output power110%-200% | |
| Protection mode: Hiccupping mode, automatically restores after the load is normal | |||
| Overvoltage | Protection mode: Hiccupping mode | ||
| Environment | Operating temperature | -20~+70℃(Please refer to the “Deduction Curve.”) | |
| Operating humidity | 20~90%RH, | ||
| Storage temperature, humidity, and temperature coefficient | -40~+85℃; 10~95%RH; ±0.05%/℃(0~50℃) | ||
| Vibration resistant | 10~500Hz,2G10 / X、Y、Z 60 | ||
| Safety regulations and electromagnetic compatibility (Note 6) | Safety standards | Ul8750 ( | |
| Withstand pressure | I/P- O/P 3.0KVAC(DC4242V) | ||
| Insulation resistance | NC | ||
| Electromagnetic compatible transmission | FCC15 | ||
| Electromagnetic compatibility immunity | NC | ||
| Others | MTBF | 100Khrs.MIL-HDBK-217F(25℃) | |
| Dimensions | 139X48X12mm(L×W×H) | ||
| Packaging | |||
| Note | 1. Unless otherwise specified, all specifications were measured at an input of 230VAC, rated load, and an ambient temperature of 25℃ | ||
| 2. Ripple and noise measurement method: Use a 12″ twisted pair cable, with the terminal connected in parallel with 0.1uF and 47uF electro-pneumatic connections, measuring at a 20MHz bandwidth | |||
| 3. Accuracy: includes setting errors and linear load adjustment rates. | |||
| 4. Linear regulation rate measurement method: Testing from low voltage to high voltage under rated load | |||
| 5. Load regulation rate measurement method: from 0% to 100% rated load | |||
| 6. The power supply should be regarded as part of the system components and should be verified in conjunction with terminal devices for electromagnetic compatibility. |